The Portable Furnace uses a heat exchanger
and distributes heat like your furnace but plugs into any standard
home wall socket and rolls easily to any location.
|
A
|
Air Inlet-
Return air enters rear of unit |
|
B
|
Fan-
Permanently lubricated, maintenance free fan moves 120 cubic
ft. of air per minute. Continuous-Duty Rated. A quiet,energy-efficient
Portable Furnace, circulates and recycles heated air through
the Lamp Chamber providing even heat from floor to ceiling. |
|
C
|
Lamps-
Four unfiltered infra-red lamps. The exclusive design of the
heat exchanger absorbs heat energy from four powerful, long-lasting
infra-red industrial lamps, converting the energy to heat
for transfer to the air. This heating approach protects recycled
air from loss of humidity. |
|
D
|
Lamp
Chamber- Nonreflective steel chamber for maximum absorption
of infra-red light energy. |
|
E
|
Thermostat |
|
F
|
Solid-State
Control Relay- Turns lamps on and off when signalled by thermostat. |
|
G
|
High-Limit
Saftey Switch- Will turn unit off if temperature of Lamp Chamber
exceeds 190 degrees. |
|
H
|
Fan Control
Switch- Operates fan motor when temperature in Lamp Chamber
reaches 90 degrees. |
|
I
|
Exclusive
Heat Exchanger- Metal plate with multiple rows of hollow venturi-tubes.
Maximum heat transfer occurs in the heat chamber as
the air passes around and through the hot tubes of the heat
exchanger, increasing air temperature for re-entering to living
area. |
|
J
|
Air Outlet
Grill- Heated energized air exits front of unit. Clean, comfortable
heated air gently flows into the living area, mixing and stabilizing
air at the floor for more even temperature distribution, and
more effective floor-level circulation and recycling. |